Home / Seren & Plasma / Human Plasma / Human Plasma Type AB Male
SeamlessBio — Human Plasma

Human Plasma — Type AB, Male Donors

Plasma from certified male AB blood-type donors — free of anti-A and anti-B antibodies. The preferred plasma format for CAR-T expansion, NK cell manufacturing, MSC culture and any immunologically sensitive cell therapy application. EU and US origin, with batch reservation for ATMP programmes.

01

No Anti-A/B Antibodies

AB blood type confirmed — universally compatible with human cells of any ABO blood group. No alloantibody-mediated interference.

02

Male Donors Only

Reduced sex hormone variability lot-to-lot — stable oestrogen and progesterone background for hormone-sensitive protocols.

03

EU & US Origin

Certified donor centres in Europe and the United States — specify origin at order. Full IVDR and GMP-process documentation available.

04

Batch Reservation

Lot reservation for ATMP programmes — no prepayment during evaluation. EU cold stock, call-off in partial deliveries as needed.

Why AB blood type — and why male donors only?

Blood group AB is the only group carrying neither anti-A nor anti-B antibodies. In all other blood groups — A, B and O — these alloantibodies circulate in plasma and can activate complement, lyse cells bearing the corresponding antigen, and create non-specific immune effects in culture systems that are difficult to distinguish from assay signal.

Restricting the donor pool to male donors addresses a second source of variability: sex hormone concentrations. Female plasma contains cyclically fluctuating oestrogens, progesterone and FSH/LH — hormones that activate steroid receptors in cultured cells, alter proliferation rates and confound results in hormone-sensitive assays. Male donors provide a consistently low and stable sex hormone background.

Together, AB blood type and male-only donor selection give the lowest alloantibody background and most consistent hormonal environment available in non-processed human plasma — which is why AB male plasma is specified in CAR-T protocols and ATMP workflows where regulatory agencies increasingly scrutinise animal-derived component profiles.

See also: Human Serum OTC Type AB Male — the serum equivalent, without coagulation factors, with higher growth factor release from platelet degranulation during clotting.

Typical applications

  • CAR-T cell manufacturing — ex vivo T cell activation and expansion media supplement
  • NK cell expansion — allogeneic cell therapy programmes
  • MSC expansion in plasma-supplemented, xeno-free protocols
  • IVD calibrator manufacturing — universal AB matrix avoids alloantibody interference
  • Complement activity studies requiring AB background
  • Cell therapy process development requiring defined, consistent plasma supplement
  • Haematopoietic stem cell (HSC) culture and expansion

AB male plasma vs. other plasma formats

ParameterAB Male PlasmaMixed Blood Group PlasmaMixed Gender Plasma
Anti-A antibodiesAbsentPresent (A/O donors)Variable
Anti-B antibodiesAbsentPresent (B/O donors)Variable
Oestrogen / progesteroneLow, stableLow, stableFluctuating
Inter-lot hormonal variabilityLowLowModerate–High
Universal cell compatibility (any ABO)YesNoDepends on mix
Preferred for CAR-T / ATMPYesNot recommendedNot recommended

Plasma vs. Serum — Type AB Male: SeamlessBio also supplies Human Serum OTC Type AB Male — produced from whole blood without anticoagulant, so it lacks coagulation factors but contains higher concentrations of platelet-released growth factors. For cell culture where coagulation factor activity is not required, off-the-clot serum is often specified. For assays requiring intact factor activity, use plasma.

Product specifications

Article numberHPAB-M
Product typeHuman Plasma, Blood Group AB, Male Donors
OriginEU or US — specify at order
Donor selectionMale donors only, blood group AB confirmed by typing
Anti-A / Anti-B antibodiesAbsent — confirmed by ABO blood group typing
AnticoagulantEDTA (K2) · Citrate (3.2%) · ACD-A — specify at order
Available formatsSingle donor units (~200–450 mL) · Pooled AB male lots · Bulk on request
StorageFresh-frozen −20°C · −80°C on request
Viral screeningHIV-1/2 Ab, HBsAg, HCV Ab, Syphilis — all negative
DocumentationCoA, CoO, MSDS, viral screening report · GMP process documentation on request
Minimum orderNo minimum order quantity
Regulatory statusFor research and IVD manufacturing use · GMP process development documentation available

Frequently asked questions

Is AB male plasma available as single units or pooled lots — or both?

Both. Single AB male donor units provide per-donor traceability and are suitable for reference panel construction. Pooled AB male lots (multiple AB male donors combined) provide a larger homogeneous volume for manufacturing and scale-up. State your preference and required volume at enquiry.

Which anticoagulant should I specify for CAR-T or NK cell expansion media?

ACD-A (Acid Citrate Dextrose Formula A) is the preferred anticoagulant for cell therapy plasma used as a media supplement — less cytotoxic at typical usage concentrations than EDTA, and commonly specified in PBMC and NK cell protocols. EDTA is standard for IVD applications. Specify your requirement at order — all three formats are available.

Can this plasma support a GMP cell therapy manufacturing process?

SeamlessBio AB male plasma is available with extended documentation to support GMP process development and manufacturing qualification — including TSE statements, donor consent documentation and manufacturing site certification where available. Discuss your specific regulatory submission requirements directly with us. Contact info@seamlessbio.de.

What is the difference between this product and Human Serum OTC Type AB Male?

Plasma is collected with anticoagulant before centrifugation and retains all coagulation factors including fibrinogen. Off-the-clot serum is obtained after natural clotting — no coagulation factors remain, but platelets degranulate during clotting and release additional growth factors (PDGF, TGF-β) into the serum. For cell culture supplementation, serum is often preferred. For applications requiring intact coagulation factor activity, use plasma. See Human Serum OTC Type AB Male →

Not sure which AB male format fits your protocol?

Contact our team — we advise on plasma vs. serum, anticoagulant format, single units vs. pooled lots, and provide a test volume before you commit.

Contact Us

Test sample of your lot

Test the exact lot before you order. If it works for you, we reserve it for up to 36 months – no prepayment.

Name