IVD Calibrator Matrix · Vitamin D Assay Development · ISO 13485 · EU Supplier

Human Processed Serum (HPS)
Vitamin D Depleted

Charcoal stripped human serum with 25-OH-D depleted to < 4 ng/mL — the standard zero-calibrator matrix for Vitamin D IVD assay kits. Also known as: Vitamin D free human serum · Vitamin D stripped serum · 25-OH-D depleted serum. 100 mL to 10+ litres. Full viral screening. No minimum order.

Human Processed Serum HPS Vitamin D Depleted IVD Calibrator SeamlessBio Germany
01

25-OH-D < 4 ng/mL

Standard residual specification. Custom residual level available — specify your target at order. Lot-specific analytical data included.

02

100 mL to 10+ L

From evaluation volumes to full IVD manufacturing runs. Same documentation and traceability at every scale. No minimum order.

03

Full Viral Screening

HIV-1/2, HBsAg, anti-HCV, Syphilis per lot. NAT screening on request. Complete donor traceability on file. CoA, CoO, TSE/BSE included.

04

EU Supplier · IVDR Ready

Based in Passau, Germany. IVDR documentation package on request. 5–10 day lead time to DACH. No import delays.

Also known as — alternative terminology

This product is referred to by different names in the IVD industry and scientific literature. SeamlessBio supplies all of the following under one product:

Industry standard term
Used by Golden West Biologicals, Molecular Depot
Used in clinical trial protocols
Processing method descriptor
Analyte-specific descriptor
IVD manufacturing term

Product Specifications

Product typeHuman Processed Serum (HPS) — Vitamin D Depleted
Depletion methodActivated charcoal stripping (dextran-coated charcoal)
Residual 25-OH-D< 4 ng/mL (standard) · custom residual level on request
Anticoagulant / baseSerum (clot-based, no anticoagulant) — standard · EDTA plasma base on request
ProcessingDelipidated + Vitamin D depleted · 0.2 µm sterile filtered
Donor poolPooled, mixed gender · full traceability on file
Viral screeningHIV-1/2 Ab, HBsAg, anti-HCV Ab, Syphilis — per lot
NAT screeningHIV-1 RNA, HCV RNA, HBV DNA — on request
Storage−20°C · Shelf life 24 months from production date
Available volumes100 mL · 500 mL · 1000 mL · 5 L · 10 L · Bulk on request
DocumentationCoA · CoO · Viral screening report · TSE/BSE statement · SDS
IVDR documentationExtended viral panel · NAT · ISO 13485 certificate — on request
Intended useManufacture of in vitro diagnostic reagents · Research use only
Minimum orderNo minimum order quantity
Lead time5–10 business days · Large volumes (≥ 5 L) on request

What is Human Processed Serum (HPS) Vitamin D Depleted?

Human Processed Serum (HPS) Vitamin D depleted is pooled human serum that has been processed by activated charcoal stripping to remove endogenous 25-hydroxyvitamin D (25-OH-D₂ and 25-OH-D₃) and 1,25-dihydroxyvitamin D to residual levels below 4 ng/mL. The matrix is also delipidated — lipoproteins removed to eliminate turbidity that would interfere with photometric assay measurements.

The result is a human serum background free of detectable Vitamin D — used as the zero-standard diluent and base matrix for Vitamin D IVD assay calibrator kits. Spiking defined concentrations of 25-OH-D₂ and/or 25-OH-D₃ into this depleted matrix produces calibrators for the full assay range.

Compatible with automated immunoassay platforms (Roche Elecsys, Abbott Architect, DiaSorin LIAISON 25-OH-D, Siemens ADVIA Centaur) and LC-MS/MS methods (isotope dilution, derivatisation-based). The human serum matrix provides endogenous binding protein background (Vitamin D Binding Protein, albumin) that matches patient samples — critical for assay accuracy across the full clinical range.

Applications

  • Vitamin D IVD assay calibrator manufacturing — zero standard and calibrator matrix
  • 25-OH-D₂ and 25-OH-D₃ kit development on automated immunoassay platforms
  • LC-MS/MS method development — turbidity-free baseline for protein precipitation
  • QC material manufacturing — low, normal and high Vitamin D controls
  • Linearity studies — serial dilution from high-positive into depleted matrix
  • Interference studies — lipemia, haemolysis and icterus assessment (IVDR Annex I)
  • EQA and proficiency testing material production
  • 1,25(OH)₂D (active Vitamin D) assay development
  • Vitamin D Binding Protein (DBP) assay development
  • Research — cell culture studies using Vitamin D-free human serum


Frequently Asked Questions

What is Human Processed Serum (HPS) and how does it differ from standard human serum?

Human Processed Serum (HPS) is human serum that has undergone additional processing — typically delipidation and charcoal stripping to remove specific analytes such as Vitamin D, steroids or hormones to below assay detection limits. Standard human serum retains all endogenous analytes and is not suitable as a zero-calibrator base for Vitamin D assays. HPS Vitamin D depleted provides a human matrix with 25-OH-D removed to < 4 ng/mL — enabling accurate calibrator preparation across the full Vitamin D assay range.

Is "Vitamin D free serum", "Vitamin D stripped serum" and "HPS Vitamin D depleted" the same product?

Yes — these terms describe the same product category. "Vitamin D free human serum" (used by Golden West Biologicals and Molecular Depot), "Vitamin D stripped serum" (used in clinical trial protocols), "charcoal stripped serum Vitamin D" and "Human Processed Serum (HPS) Vitamin D depleted" (SEQENS IVD / Avantor nomenclature) all refer to human serum processed by charcoal stripping to remove 25-OH-D to < 4 ng/mL. SeamlessBio supplies this product regardless of which terminology your specification uses.

What volumes are available — can I order 10 litres?

Yes. SeamlessBio supplies HPS Vitamin D depleted from 100 mL evaluation volumes up to 10 litres and beyond for IVD manufacturing runs. Large volume orders (≥ 1 L) are supplied with lot-specific CoA, full donor traceability and viral screening documentation. Batch reservation for production lifecycle supply is available without prepayment. Contact info@seamlessbio.de with your required volume and specification for a quote within 48 hours.

Can I specify a custom residual 25-OH-D level?

Yes. Standard specification is residual 25-OH-D < 4 ng/mL (undetectable on most immunoassay platforms). Custom residual levels — for example < 2 ng/mL for LC-MS/MS methods with lower detection limits, or a defined low concentration for spike-recovery validation — can be specified on request. Lot-specific Vitamin D analytical data is included with each shipment.

What documentation is included for IVDR technical files?

Standard documentation per lot: Certificate of Analysis (CoA), Certificate of Origin (CoO), viral screening report (HIV-1/2, HBsAg, anti-HCV, Syphilis), TSE/BSE statement, Safety Data Sheet (SDS), complete donor traceability on file. Extended IVDR package on request: NAT screening (HIV-1 RNA, HCV RNA, HBV DNA), extended viral panel (anti-HBc, anti-HTLV, HAV Ab), ISO 13485 manufacturer certificate, IVDR Annex I Annex II documentation support.

Is this product suitable for use in IVD manufacturing?

Yes. HPS Vitamin D depleted from SeamlessBio is intended for the manufacture of in vitro diagnostic reagents — calibrators, controls, standards and EQA specimens. Not for therapeutic use or direct administration to humans. Full IVD-grade documentation available. For GMP-grade material with extended documentation, contact info@seamlessbio.de.

Request HPS Vitamin D Depleted

Specify your required volume (100 mL to 10+ L), residual 25-OH-D level and documentation requirements — quote within 48 hours. Free evaluation sample available on request.

Need a Lot Reservation or Test Sample?

Reserve your validated FBS or human serum lot — no prepayment.