HEK293 & CHO · Research to GMP

Transient Transfection: Media, Kits and Protocols for HEK293 and CHO

Everything you need for transient expression in one place: matched transfection kits for HEK293, CHO and viral vectors, serum-free and chemically defined media, and the protocol questions that decide your yield.

HEK293 & HEK293TCHOAAV & lentiviral vectorsSerum-free & chemically definedGMP grade

Transient transfection gets protein or vector into your hands in days instead of months. No stable cell line, no clone selection. But yield depends on a handful of decisions: which cell line, which medium, which reagent, what cell density at the moment of transfection, and when you harvest. This page covers those decisions and points to the products and the detailed articles behind each one.

Transfection kits

Each kit brings basal medium, feed, enhancer and transfection reagent together as one matched system, so you aren't combining components from different sources and hoping they work together. All kits are GMP grade, made by a manufacturer certified to ISO 13485, ISO 9001 and EXCiPACT, with CoA, SDS and traceability records per batch. Media are also available as powder for larger volumes.

Choosing your system: HEK293 or CHO

Both work for transient expression, but they suit different goals.

QuestionHEK293 / HEK293TCHO
Typical useViral vectors, difficult proteins, fast material for researchAntibodies and proteins intended for later stable production
Transient yieldGenerally higher per litreLower transiently, but matches the later production host
GlycosylationHuman-typeHamster-type, the industry standard for biologics
Why it mattersSpeed and vector productionMaterial that behaves like your final product

If the protein is destined for a CHO production line, transient CHO material tells you more about the final molecule. If you need vector or a hard-to-express protein quickly, HEK293 is usually the faster route.

What actually decides your yield

1

Cell density and viability at transfection

This is the single most common reason for a disappointing run. Cells must be in active growth, not just alive. Viability below roughly 95 % at the moment of transfection costs yield that no amount of reagent optimisation recovers.

2

DNA to reagent ratio

Worth re-optimising whenever you change medium, cell line or plasmid. A ratio carried over from a different system is a frequent cause of low expression or unexpected toxicity.

3

Medium compatibility

Transfection reagents behave differently in different media. Components that help cells grow can reduce complex formation. This is why a matched kit removes a variable rather than adding one.

4

Feed and enhancer timing

Transient cultures crash when nutrients run out before expression peaks. Feeding at the right point, not simply feeding more, is what extends the production window.

5

Harvest time

Harvest too early and you leave product behind; too late and you collect degraded product and host-cell protein. The right point differs for secreted protein and for vector held inside the cells.

Frequently Asked Questions

What is transient transfection?

DNA is introduced into cells and expressed without being integrated into the genome. Expression lasts days rather than permanently, which is why it suits fast material supply and vector production. No clone selection is needed, so you get material in days instead of months.

HEK293 or CHO for transient expression?

HEK293 generally gives higher transient yields and is the standard host for AAV and lentiviral vectors. CHO gives material that behaves like a later CHO production run, including glycosylation, which matters if the molecule is headed for stable CHO manufacturing.

Do I need a matched kit, or can I combine components?

You can combine them, and many labs do. A matched kit removes the compatibility question between reagent, medium, feed and enhancer, which is where a lot of troubleshooting time goes. If your current system works, there is no reason to change it.

Can I test a medium or kit before ordering?

Yes. We send an evaluation sample so you can test it with your own cells and process. Testing usually takes 6–8 weeks, so it's worth starting before you need the material.

Is there a minimum order, and can you reserve a batch?

There is no minimum order, from a single pack to a production campaign. We can reserve a batch for your campaign so your process stays on the material you qualified.

Are these products GMP grade?

The CelliMax kits and media are GMP grade, made by a manufacturer certified to ISO 13485, ISO 9001 and EXCiPACT, with CoA, SDS and traceability records per batch. They are raw materials for research, process development and further manufacturing, not for direct use in humans.

Tell us what you're expressing

Cell line, scale and timeline — we'll tell you which kit or medium fits, and send a test sample so you can try it with your own cells.

Test sample of your lot

Test the exact lot before you order. If it works for you, we reserve it for up to 36 months – no prepayment.

Name