Description
.sb-pd{font-family:-apple-system,BlinkMacSystemFont,”Segoe UI”,Roboto,sans-serif;max-width:100%;color:#202020;line-height:1.75}
.sb-pd .def{background:#e9fbfa;border-left:4px solid #18b7b2;border-radius:0 10px 10px 0;padding:16px 20px;margin:0 0 28px}
.sb-pd .def .lb{font-size:11px;font-weight:800;text-transform:uppercase;letter-spacing:.09em;color:#139b97;display:block;margin-bottom:5px}
.sb-pd .def p{font-size:15px;margin:0;font-weight:500}
.sb-pd h2{font-size:21px;font-weight:800;margin:32px 0 10px;color:#111;border-bottom:2px solid #e2eceb;padding-bottom:7px}
.sb-pd h3{font-size:15px;font-weight:700;color:#18b7b2;margin:18px 0 5px}
.sb-pd p{margin:0 0 12px;font-size:15px}
.sb-pd ul{margin:0 0 12px;padding-left:20px}
.sb-pd li{margin-bottom:6px;font-size:14px}
.sb-pd .cards{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0 20px}
.sb-pd .card{background:#f1faf9;border:1px solid #daf3f2;border-top:3px solid #18b7b2;border-radius:0 0 10px 10px;padding:14px}
.sb-pd .card h3{margin:0 0 5px;font-size:13px;color:#111}
.sb-pd .card p{margin:0;font-size:12px;color:#5b6b71}
.sb-pd table{width:100%;border-collapse:collapse;font-size:14px;margin:14px 0 20px}
.sb-pd th{background:#18b7b2;color:#fff;text-align:left;padding:9px 13px;font-weight:700}
.sb-pd td{padding:9px 13px;border-bottom:1px solid #e2eceb;vertical-align:top}
.sb-pd tr:nth-child(even) td{background:#f8fffe}
.sb-pd td:first-child{font-weight:600;color:#111;width:35%}
.sb-pd .qa{background:#f8fffe;border:1px solid #daf3f2;border-radius:8px;padding:14px 16px;margin:10px 0}
.sb-pd .qa .q{font-weight:700;color:#111;margin:0 0 5px;font-size:14px}
.sb-pd .qa .a{margin:0;font-size:13px;color:#444}
.sb-pd .cta{background:linear-gradient(135deg,#e4f6f5,#f4fbfb);border:1px solid rgba(24,183,178,.2);border-radius:12px;padding:20px;margin-top:28px;text-align:center}
.sb-pd .cta h3{margin:0 0 7px;font-size:17px;color:#111}
.sb-pd .cta p{margin:0 0 14px;font-size:13px;color:#5b6b71}
.sb-pd .btn{display:inline-block;background:#18b7b2;color:#fff!important;padding:9px 20px;border-radius:7px;font-weight:700;font-size:13px;text-decoration:none!important;margin:0 4px}
.sb-pd .btn-o{display:inline-block;border:2px solid #18b7b2;color:#18b7b2!important;padding:7px 20px;border-radius:7px;font-weight:700;font-size:13px;text-decoration:none!important;margin:0 4px}
.sb-pd a{color:#18b7b2;font-weight:600}
@media(max-width:600px){.sb-pd .cards{grid-template-columns:1fr}}
Product Overview
Comprehensive Overview of the Human Control Vesicle Kit
The Human Control Vesicle Kit (HEK293 derived) provides inside-out membrane vesicles prepared from HEK293 cells transfected with empty vector (no transporter). These matched control vesicles are produced using the identical process as all Cell4Pharma transporter vesicle kits — ensuring that any non-specific compound uptake, lipid interactions, or background transport is fully captured and subtracted from assay data. Use of matched control vesicles alongside transporter vesicles is essential for valid substrate classification, reliable IC₅₀ determination, and regulatory-grade data quality.
Transporter Profile
Control vesicles contain no overexpressed transporter — they are prepared from the identical HEK293 cell background used for all Cell4Pharma transporter kits, transfected with empty vector only. This matched background ensures that any compound accumulation detected in the ATP condition of control vesicles reflects non-specific membrane partitioning, lipid binding, or endogenous transporter activity — not specific ABC transporter-mediated uptake. The ATP/AMP-dependent transport ratio for the active transporter kit is calculated by comparing with these matched control vesicles. FDA and EMA guidance specify use of matched control vesicles in vesicular transport assays.
Technical Specifications
| Parameter | Specification |
|---|---|
| Transporter | Control Vesicles (HEK293 empty vector) (HEK293 empty vector — no transporter) |
| Expression system | HEK293 (transient overexpression) |
| Vesicle type | Inside-out membrane vesicles |
| Reactions per kit | 100 |
| ATP/AMP transport ratio | N/A — matched control (empty vector) |
| Detection compatibility | Matched to all detection methods (radiolabel, LC-MS/MS, fluorescence) |
| Storage | −80 °C (supplied on dry ice) |
| Kit contents | Vesicles, ATP, AMP, reaction buffer, wash buffer, CoA |
| Manufacturer | Cell4Pharma (Netherlands) |
| Distributor DACH | SeamlessBio, Passau |
Applications
| Application | Description |
|---|---|
| Matched negative control for all ABC transporter assays | Required alongside every transporter vesicle kit — BCRP, BSEP, MRP1–8, Pgp. Enables accurate calculation of specific transporter-mediated uptake by subtracting background vesicle accumulation. |
| Non-specific binding and lipid partitioning assessment | Highly lipophilic compounds can partition into membrane lipids independently of transporters. Control vesicles quantify this background for accurate net transport calculation. |
| Regulatory-grade data generation | FDA and EMA require use of matched control membranes in vesicular transport assays to demonstrate transporter specificity. Control vesicle data must be included in regulatory submission packages. |
Assay Principle
Inside-out membrane vesicles present the cytoplasmic face of the transporter to the assay buffer, allowing ATP-dependent substrate uptake into the vesicle lumen. Incubate vesicles with test compound and probe substrate in the presence of ATP (transport) or AMP (background control). Stop reaction with cold wash buffer, separate vesicles by filtration, and quantify accumulated substrate by LC-MS/MS, radiolabel, or fluorescence. The ATP/AMP ratio provides the assay window for reliable IC₅₀ determination.
Complete Cell4Pharma Kit Portfolio at SeamlessBio
Order all ABC transporter vesicle kits from a single EU source — fast cold-chain delivery, guaranteed ATP/AMP ratios, full documentation.
| Kit | Transporter | Gene | ATP/AMP Ratio |
|---|---|---|---|
| Human BCRP Vesicle Kit | BCRP | ABCG2 | >10 |
| Human BSEP Vesicle Kit | BSEP | ABCB11 | >10 |
| Human MRP1 Vesicle Kit | MRP1 | ABCC1 | >5 |
| Human MRP2 Vesicle Kit | MRP2 | ABCC2 | >10 |
| Human MRP3 Vesicle Kit | MRP3 | ABCC3 | >10 |
| Human MRP4 Vesicle Kit | MRP4 | ABCC4 | >5 |
| Human MRP5 Vesicle Kit | MRP5 | ABCC5 | >3 |
| Human MRP8 Vesicle Kit | MRP8 | ABCC11 | >3 |
| Human Pgp Vesicle Kit | P-gp / MDR1 | ABCB1 | >5 |
| Human Pgp + FluoPgp Kit | P-gp / MDR1 | ABCB1 | >5 |
| Human Control Vesicle Kit | — | HEK293 empty vector | — |
Quality & Regulatory Compliance
- Produced by Cell4Pharma — specialist manufacturer of ABC transporter vesicle systems
- Guaranteed ATP/AMP transport ratio N/A (matched control) per lot
- Large, uniform batches — maximum lot-to-lot consistency
- Lot-specific QC report + data sheet included with every kit
- Aligned with FDA DDI Guidance (2020) and EMA DDI Guideline (2013/2022)
Why Order via SeamlessBio?
| Advantage | Description |
|---|---|
| ✅ EU warehouse stock | Fast cold-chain delivery across Germany, Austria, Switzerland and the EU |
| ✅ Direct contact | Speak to a scientist, not a call centre — in German or English |
| ✅ Full documentation | Data sheet, QC report and invoice with every shipment |
| ✅ Batch reservation | Reserve a specific lot for your entire project duration |
| ✅ Complete portfolio | All 11 Cell4Pharma kits from one source — BCRP, BSEP, MRP1–8, Pgp, Control |
Order or request pricing: info@seamlessbio.de | +49 851 37932226
Frequently Asked Questions
Must I use control vesicles with every transporter kit?
Yes — matched control vesicles are required for valid assay interpretation. FDA and EMA both specify the use of matched empty-vector or mock-transfected control membranes. Data generated without matched controls is not considered regulatory-grade and may not be accepted in DDI submissions. We recommend ordering one control kit per transporter kit used.
Are the control vesicles produced from the same cell batch as the transporter vesicles?
Cell4Pharma control vesicles are produced from the identical HEK293 cell line background under the same manufacturing conditions as all transporter vesicle kits — ensuring maximum matching for membrane composition, endogenous transporter expression, and lipid profile.
What is the Human Control Vesicle Kit?
The Human Control Vesicle Kit is an essential tool derived from HEK293 cells, designed specifically as an empty vector and negative control for various ABC transporter assays. This kit provides researchers with highly purified control vesicles, ensuring that experiments measuring transporter activity remain accurate and reliable. By utilizing human cell-derived vesicles without any expressed transporter proteins, it helps eliminate background noise and validates assay specificity, making it indispensable for drug discovery and transporter function studies.
Key Features and Benefits of the Kit
The kit includes vesicles prepared from HEK293 cells transfected with an empty vector, serving as an ideal negative control. This assures that any measured transport activity in assays can be confidently attributed to the transporter of interest. The vesicles exhibit high stability and are compatible with a range of substrates and inhibitors, enabling precise characterization of ABC transporters. Additionally, the quality-controlled preparation simplifies experimental workflows, saving time while enhancing reproducibility in your research.
Applications in ABC Transporter Research
Using the Human Control Vesicle Kit is crucial when evaluating efflux transporter activity, including P-glycoprotein, MRP family, and BCRP assays. This negative control provides a baseline to differentiate between specific transporter-mediated transport and nonspecific substrate interactions. It supports assay development, validation, and screening of novel drugs targeting ABC transporters. Overall, the kit improves confidence in data interpretation, contributing to the successful identification of transporter inhibitors or substrates in pharmaceutical development.
Available Formats
| Format | Size |
|---|---|
| Test | 100 |
Key Benefits
Batch Reservation
Reserve validated lots up to 36 months for reproducible long-term workflows.
Full Documentation
CoA, BSE/TSE, sterility certificate and additional documents on request.
EU Stock
Warehoused in Passau, Germany — fast delivery across EU, UK and Switzerland.
Frequently Asked Questions
1
1
2
2
3
3
Request a Quote or Sample
48h response · EU Stock · Batch reservation available · Full documentation
Request Quote →
All ABC Transporter Kits →MRP Transporters Guide →What is MRP2? →What is BSEP? →Request Quote →