Human Control Vesicle Kit (HEK293 derived) | Negative Control for ABC Transporter Assays

Price on request

Human Control Vesicle Kit (HEK293 derived) | Empty Vector | Negative Control for All ABC Transporter Assays. Available in 100. Price on request — contact our team for availability, batch documentation and delivery.

Request Quote

Description

.sb-pd{font-family:-apple-system,BlinkMacSystemFont,”Segoe UI”,Roboto,sans-serif;max-width:100%;color:#202020;line-height:1.75}
.sb-pd .def{background:#e9fbfa;border-left:4px solid #18b7b2;border-radius:0 10px 10px 0;padding:16px 20px;margin:0 0 28px}
.sb-pd .def .lb{font-size:11px;font-weight:800;text-transform:uppercase;letter-spacing:.09em;color:#139b97;display:block;margin-bottom:5px}
.sb-pd .def p{font-size:15px;margin:0;font-weight:500}
.sb-pd h2{font-size:21px;font-weight:800;margin:32px 0 10px;color:#111;border-bottom:2px solid #e2eceb;padding-bottom:7px}
.sb-pd h3{font-size:15px;font-weight:700;color:#18b7b2;margin:18px 0 5px}
.sb-pd p{margin:0 0 12px;font-size:15px}
.sb-pd ul{margin:0 0 12px;padding-left:20px}
.sb-pd li{margin-bottom:6px;font-size:14px}
.sb-pd .cards{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0 20px}
.sb-pd .card{background:#f1faf9;border:1px solid #daf3f2;border-top:3px solid #18b7b2;border-radius:0 0 10px 10px;padding:14px}
.sb-pd .card h3{margin:0 0 5px;font-size:13px;color:#111}
.sb-pd .card p{margin:0;font-size:12px;color:#5b6b71}
.sb-pd table{width:100%;border-collapse:collapse;font-size:14px;margin:14px 0 20px}
.sb-pd th{background:#18b7b2;color:#fff;text-align:left;padding:9px 13px;font-weight:700}
.sb-pd td{padding:9px 13px;border-bottom:1px solid #e2eceb;vertical-align:top}
.sb-pd tr:nth-child(even) td{background:#f8fffe}
.sb-pd td:first-child{font-weight:600;color:#111;width:35%}
.sb-pd .qa{background:#f8fffe;border:1px solid #daf3f2;border-radius:8px;padding:14px 16px;margin:10px 0}
.sb-pd .qa .q{font-weight:700;color:#111;margin:0 0 5px;font-size:14px}
.sb-pd .qa .a{margin:0;font-size:13px;color:#444}
.sb-pd .cta{background:linear-gradient(135deg,#e4f6f5,#f4fbfb);border:1px solid rgba(24,183,178,.2);border-radius:12px;padding:20px;margin-top:28px;text-align:center}
.sb-pd .cta h3{margin:0 0 7px;font-size:17px;color:#111}
.sb-pd .cta p{margin:0 0 14px;font-size:13px;color:#5b6b71}
.sb-pd .btn{display:inline-block;background:#18b7b2;color:#fff!important;padding:9px 20px;border-radius:7px;font-weight:700;font-size:13px;text-decoration:none!important;margin:0 4px}
.sb-pd .btn-o{display:inline-block;border:2px solid #18b7b2;color:#18b7b2!important;padding:7px 20px;border-radius:7px;font-weight:700;font-size:13px;text-decoration:none!important;margin:0 4px}
.sb-pd a{color:#18b7b2;font-weight:600}
@media(max-width:600px){.sb-pd .cards{grid-template-columns:1fr}}

Product Overview

Comprehensive Overview of the Human Control Vesicle Kit

The Human Control Vesicle Kit (HEK293 derived) provides inside-out membrane vesicles prepared from HEK293 cells transfected with empty vector (no transporter). These matched control vesicles are produced using the identical process as all Cell4Pharma transporter vesicle kits — ensuring that any non-specific compound uptake, lipid interactions, or background transport is fully captured and subtracted from assay data. Use of matched control vesicles alongside transporter vesicles is essential for valid substrate classification, reliable IC₅₀ determination, and regulatory-grade data quality.

Transporter Profile

Control vesicles contain no overexpressed transporter — they are prepared from the identical HEK293 cell background used for all Cell4Pharma transporter kits, transfected with empty vector only. This matched background ensures that any compound accumulation detected in the ATP condition of control vesicles reflects non-specific membrane partitioning, lipid binding, or endogenous transporter activity — not specific ABC transporter-mediated uptake. The ATP/AMP-dependent transport ratio for the active transporter kit is calculated by comparing with these matched control vesicles. FDA and EMA guidance specify use of matched control vesicles in vesicular transport assays.

Technical Specifications

ParameterSpecification
TransporterControl Vesicles (HEK293 empty vector) (HEK293 empty vector — no transporter)
Expression systemHEK293 (transient overexpression)
Vesicle typeInside-out membrane vesicles
Reactions per kit100
ATP/AMP transport ratioN/A — matched control (empty vector)
Detection compatibilityMatched to all detection methods (radiolabel, LC-MS/MS, fluorescence)
Storage−80 °C (supplied on dry ice)
Kit contentsVesicles, ATP, AMP, reaction buffer, wash buffer, CoA
ManufacturerCell4Pharma (Netherlands)
Distributor DACHSeamlessBio, Passau

Applications

ApplicationDescription
Matched negative control for all ABC transporter assaysRequired alongside every transporter vesicle kit — BCRP, BSEP, MRP1–8, Pgp. Enables accurate calculation of specific transporter-mediated uptake by subtracting background vesicle accumulation.
Non-specific binding and lipid partitioning assessmentHighly lipophilic compounds can partition into membrane lipids independently of transporters. Control vesicles quantify this background for accurate net transport calculation.
Regulatory-grade data generationFDA and EMA require use of matched control membranes in vesicular transport assays to demonstrate transporter specificity. Control vesicle data must be included in regulatory submission packages.

Assay Principle

Inside-out membrane vesicles present the cytoplasmic face of the transporter to the assay buffer, allowing ATP-dependent substrate uptake into the vesicle lumen. Incubate vesicles with test compound and probe substrate in the presence of ATP (transport) or AMP (background control). Stop reaction with cold wash buffer, separate vesicles by filtration, and quantify accumulated substrate by LC-MS/MS, radiolabel, or fluorescence. The ATP/AMP ratio provides the assay window for reliable IC₅₀ determination.

Complete Cell4Pharma Kit Portfolio at SeamlessBio

Order all ABC transporter vesicle kits from a single EU source — fast cold-chain delivery, guaranteed ATP/AMP ratios, full documentation.

KitTransporterGeneATP/AMP Ratio
Human BCRP Vesicle KitBCRPABCG2>10
Human BSEP Vesicle KitBSEPABCB11>10
Human MRP1 Vesicle KitMRP1ABCC1>5
Human MRP2 Vesicle KitMRP2ABCC2>10
Human MRP3 Vesicle KitMRP3ABCC3>10
Human MRP4 Vesicle KitMRP4ABCC4>5
Human MRP5 Vesicle KitMRP5ABCC5>3
Human MRP8 Vesicle KitMRP8ABCC11>3
Human Pgp Vesicle KitP-gp / MDR1ABCB1>5
Human Pgp + FluoPgp KitP-gp / MDR1ABCB1>5
Human Control Vesicle Kit—HEK293 empty vector—

Quality & Regulatory Compliance

  • Produced by Cell4Pharma — specialist manufacturer of ABC transporter vesicle systems
  • Guaranteed ATP/AMP transport ratio N/A (matched control) per lot
  • Large, uniform batches — maximum lot-to-lot consistency
  • Lot-specific QC report + data sheet included with every kit
  • Aligned with FDA DDI Guidance (2020) and EMA DDI Guideline (2013/2022)

Why Order via SeamlessBio?

AdvantageDescription
✅ EU warehouse stockFast cold-chain delivery across Germany, Austria, Switzerland and the EU
✅ Direct contactSpeak to a scientist, not a call centre — in German or English
✅ Full documentationData sheet, QC report and invoice with every shipment
✅ Batch reservationReserve a specific lot for your entire project duration
✅ Complete portfolioAll 11 Cell4Pharma kits from one source — BCRP, BSEP, MRP1–8, Pgp, Control

Order or request pricing: info@seamlessbio.de | +49 851 37932226

Frequently Asked Questions

Must I use control vesicles with every transporter kit?

Yes — matched control vesicles are required for valid assay interpretation. FDA and EMA both specify the use of matched empty-vector or mock-transfected control membranes. Data generated without matched controls is not considered regulatory-grade and may not be accepted in DDI submissions. We recommend ordering one control kit per transporter kit used.

Are the control vesicles produced from the same cell batch as the transporter vesicles?

Cell4Pharma control vesicles are produced from the identical HEK293 cell line background under the same manufacturing conditions as all transporter vesicle kits — ensuring maximum matching for membrane composition, endogenous transporter expression, and lipid profile.

What is the Human Control Vesicle Kit?

The Human Control Vesicle Kit is an essential tool derived from HEK293 cells, designed specifically as an empty vector and negative control for various ABC transporter assays. This kit provides researchers with highly purified control vesicles, ensuring that experiments measuring transporter activity remain accurate and reliable. By utilizing human cell-derived vesicles without any expressed transporter proteins, it helps eliminate background noise and validates assay specificity, making it indispensable for drug discovery and transporter function studies.

Key Features and Benefits of the Kit

The kit includes vesicles prepared from HEK293 cells transfected with an empty vector, serving as an ideal negative control. This assures that any measured transport activity in assays can be confidently attributed to the transporter of interest. The vesicles exhibit high stability and are compatible with a range of substrates and inhibitors, enabling precise characterization of ABC transporters. Additionally, the quality-controlled preparation simplifies experimental workflows, saving time while enhancing reproducibility in your research.

Applications in ABC Transporter Research

Using the Human Control Vesicle Kit is crucial when evaluating efflux transporter activity, including P-glycoprotein, MRP family, and BCRP assays. This negative control provides a baseline to differentiate between specific transporter-mediated transport and nonspecific substrate interactions. It supports assay development, validation, and screening of novel drugs targeting ABC transporters. Overall, the kit improves confidence in data interpretation, contributing to the successful identification of transporter inhibitors or substrates in pharmaceutical development.

Available Formats

FormatSize
Test100

Key Benefits

Batch Reservation

Reserve validated lots up to 36 months for reproducible long-term workflows.

Full Documentation

CoA, BSE/TSE, sterility certificate and additional documents on request.

EU Stock

Warehoused in Passau, Germany — fast delivery across EU, UK and Switzerland.

Frequently Asked Questions

1

1

2

2

3

3

Request a Quote or Sample

48h response · EU Stock · Batch reservation available · Full documentation

Request Quote →
All ABC Transporter Kits →MRP Transporters Guide →What is MRP2? →What is BSEP? →Request Quote →

Additional information

Test

100

Request a Quote or Sample

48h response · EU Stock · Batch reservation available · Full documentation

Sample Request →