2D Bags · 3D Bioreactor Bags · Rocker Bags · Bag Assemblies · Tank Liners · Container Systems

Single-Use Bioprocessing

Complete single-use bioprocessing portfolio — 2D and 3D bags, rocker/wave bags (10–50 L), pre-configured bag assemblies, tank liners and stainless steel container systems (200L–1000L). USP Class VI film, gamma-sterilised, leak tests in validation. All products available on request.

USP Class VI Gamma-Sterilised Integrity-Tested 2D · 3D · Rocker · Assemblies 200L–1000L Container

Single-use bioprocessing bags – made to your process

Request a quote – built to your drawing, gamma-sterilised (SAL 10⁻⁶), CoA with every lot. About 2–3 weeks for 100 units.

Request a quote →

Product Overview

ProductVolumesApplication
2D Bags150 mL – 50 LStorage, freeze-thaw, buffer
3D Bags100 L – 1,000 LBioreactor, large-scale storage
Rocker Bags10 L – 50 LWave bioreactor, cell culture
Bag Assemblies150 mL – 1,000 LFluid management, closed-system processing
Tank Liners100 L, 500 L, 1,000 LSS tank lining, CIP/SIP elimination
Container Systems200L, 500L, 1000LLarge-scale buffer/media hold

Certifications and detailed specifications available on request.

At a glance

We supply single-use bags for cell culture and bioprocessing, made to your process: 2D bags from 150 mL to 50 L, 3D bags from 100 L to 1,000 L, rocker bags from 10 L to 50 L and tank liners. Each bag is configured to your process – film, ports, tubing, connectors, filters and sampling.

Where our bags are used

Process stepBag
Media and buffer preparation2D bags up to 50 L; 3D bags for large-volume media, buffer and WFI hold
Seed train and cell expansionRocker bags from 10 L to 50 L for rocking bioreactors; smaller on request
Bioreactor harvest3D bags with MPX connections for sterile collection of culture supernatant
Downstream holdIntermediate storage between chromatography, filtration and UF/DF
Bulk drug substance3D film rated to −80 °C for storage and freezing
Stainless steel tanksTank liners of 100, 500 and 1,000 L – no CIP/SIP between batches

Specifications for all bags

ParameterSpecification
SterilisationGamma irradiated, SAL 10⁻⁶ (ISO 11137)
ManufacturingISO Class 7 cleanroom
MaterialsAnimal-derived component free (ADCF), USP Class VI; 3D bags also ISO 10993
DocumentationBatch-specific CoA and CoO, leachables/extractables/tox validation guide
Shelf lifeDetermined by accelerated ageing (ASTM F1980); expiry date on every label
Stock and deliveryMade to order; contact and invoicing in Germany or Switzerland

Configure your bag: what you can choose

Every bag is built to your process. Pick the options below and the drawing changes with you. Then send us the configuration and we reply with a quote and lead time.

Single-use bag assembly with the parts you can choose10 LPE/EVOHMPC6MPC7123455
1 Volume2 Film3 Ports4 Tubing5 Connectors6 Filters7 Sampling port

Your configuration

    Send this configuration by e-mail Request a quote

    Tubing lengths, diameters and anything not listed here we agree with you directly.

    What each number stands for

    ComponentOptions
    1 Volume2D: 150 mL, 500 mL, 1, 5, 10, 20 and 50 L. 3D: 100, 200, 500 and 1,000 L. Rocker bags: 10–50 L, smaller on request. Tank liners: 100, 500 and 1,000 L.
    2 FilmMultilayer PE/EVOH with gas barrier (standard; fluid contact ULDPE on 3D bags), PE/EVA multilayer, or a custom film for chemical resistance or freezing. Freeze–thaw tested to −80 °C.
    3 Ports and manifoldFrom the standard 3-port layout to custom multi-line manifolds. On 3D bags also dip tubes and sensor ports.
    4 TubingWeldable TPE or platinum-cured silicone, in the lengths and diameters you need.
    5 ConnectorsMPC, MPX (standard on 3D bags), Luer Lock, hose barb 1/8″ and 1/4″, Tri-Clamp, septum and sterile connectors.
    6 Filters0.2 µm PTFE vent filter; sterilising-grade PES filter in the line.
    7 Sampling portNeedle-free or Luer Lock sampling port.

    Already using single-use bags? Send us the item number or drawing of the bag you use today. We build a matching assembly with your existing connectors.

    How to order

    Sample on request

    Test the bag in your own process before you order.

    Pilot lots from 100 units

    From pilot lots of 100 units to serial supply.

    Delivery from Germany

    Made to order; contact and invoicing in Germany or Switzerland.

    More questions about single-use bags

    Will your bags fit our existing hardware?

    Send us the item number or drawing of your current bag and the model of your hardware. We build a matching bag with your existing connectors and check the fit before production.

    Which film do you use for cell culture media?

    As standard a multilayer PE/EVOH film with gas barrier, free of animal-derived components and USP Class VI. For special chemical resistance or freezing we offer other film structures.

    How are the bags sterilised and documented?

    They are made in an ISO Class 7 cleanroom and gamma irradiated to SAL 10⁻⁶ (ISO 11137). Each batch comes with CoA and CoO; a leachables, extractables and tox validation guide is available.

    Is there a minimum order quantity?

    Yes: pilot lots start at 100 units, and serial supply follows after drawing approval. Typical lead time: 2–3 weeks for 100 units.

    Ordering from Switzerland? Order single-use bioprocessing bags via Seamless Bio GmbH →
    Invoiced in CHF with Swiss VAT by Seamless Bio GmbH · no import customs clearance

    Frequently Asked Questions

    What is the difference between 2D and 3D bioprocessing bags?

    2D bags are flat for storage and freeze-thaw. 3D bags have a cuboid shape for larger volumes and bioreactor use — better space efficiency above 20L.

    What is a single-use bag assembly?

    A pre-configured system combining a bioprocess bag with tubing, connectors and optional filters — ready to use without in-house assembly. Available in 2D format (150 mL–50 L) and 3D format (100 L–1,000 L).

    What container sizes are available?

    Stainless steel container systems in 200L, 500L and 1000L with integrated single-use liner. Other sizes on request.

    Can bags be customised?

    Yes — custom port configurations, tubing assemblies and bag dimensions available on request. Contact us with your specifications.

    Request a Quote

    Tell us your format, volume and application — we will get back to you promptly.

    Test sample of your lot

    Test the exact lot before you order. If it works for you, we reserve it for up to 36 months – no prepayment.

    Name