Bovine IgG from serum gets into purified antibodies and disturbs some assays. This protocol shows how to deplete it from FBS with a Protein G column and how to check the residual IgG.
Buy fetal bovine serum (FBS) from EU stock
Request a quote or a test sample – EU stock, no minimum order, lot reservation up to 36 months.
Why remove bovine IgG
When you purify an antibody from culture supernatant with Protein A or Protein G, bovine IgG from the serum binds as well and ends up in your product. In Fc receptor studies and some immunoassays, serum IgG also interferes with the readout. IgG-depleted serum removes most of this background.
How it works
The serum is passed over a column with immobilised Protein G. Protein G binds both bovine IgG subclasses strongly, while Protein A binds bovine IgG less well. That is why Protein G is the usual choice. The serum that runs through the column, the flow-through, is your IgG-depleted serum.
Materials
- FBS, thawed slowly at 2–8 °C and prefiltered through 0.45 µm
- Protein G column or resin; check the binding capacity for bovine IgG in the manufacturer’s data
- Binding buffer: PBS pH 7.2–7.4
- Elution buffer for regeneration: 0.1 M glycine pH 2.5–3.0
- Pump or gravity flow setup, sterile collection bottles
- 0.2 µm sterile filter with low protein binding (PES)
Step-by-step protocol
1. Size and equilibrate the column
- Estimate the IgG amount in your serum volume and choose a column with a clear safety margin in capacity. An overloaded column lets IgG through.
- Equilibrate the column with 5–10 column volumes of PBS.
2. Load the serum
- Apply the serum at a slow flow rate, so each part of the serum stays in contact with the resin for several minutes.
- Discard the first fraction that only contains buffer from the column. Collect the flow-through as soon as serum appears.
- Chase the last serum through the column with a small volume of PBS and collect it too. Note the total volume, because the serum is slightly diluted.
3. Second pass for lower residual IgG
- Regenerate the column: elute the bound IgG with glycine buffer and re-equilibrate with PBS.
- Pass the flow-through over the column a second time. Two passes give clearly lower residual IgG than one.
4. Filter, aliquot, store
- Sterile-filter the depleted serum through 0.2 µm. The column run is not a sterile process.
- Aliquot, label as “IgG-depleted” with date and lot, and store at −20 °C.
Quality control
- Residual IgG: measure bovine IgG before and after with a bovine IgG ELISA or radial immunodiffusion.
- Total protein and osmolality: show how much the serum was diluted.
- Growth: test your hybridoma or production cell line in the final medium before scaling up.
Practical tips
- Do not reuse a column for different serum lots without full regeneration and cleaning.
- Use IgG-depleted serum mainly in the production phase. Fusion and cloning usually work better with standard FBS.
- For large volumes, buying low-IgG FBS is usually more economical than depleting in the lab.
Frequently asked questions
Protein A or Protein G for depleting bovine IgG?
Protein G. It binds both bovine IgG subclasses strongly. Protein A binds bovine IgG weaker and leaves more IgG in the serum.
Does IgG depletion change growth support?
Usually only a little, because growth factors and albumin pass through the column. Test your cell line anyway, since the serum is slightly diluted.
Which IgG levels do your low-IgG FBS grades have?
FBS Low IgG has less than 200 µg/mL bovine IgG, FBS Ultra Low IgG less than 5 µg/mL. A test sample is available on request.