← All serum protocols

Some experiments need serum without hormones and without active complement. This protocol shows how to combine charcoal stripping and heat inactivation, in which order, and how to check the result.

When you need both treatments

Charcoal stripping removes steroid and thyroid hormones. Heat inactivation switches off complement. You need both when a hormone experiment runs with cells or readouts that react to complement, for example hormone studies with immune cells, antibody-based readouts or long co-cultures.

If your assay is not affected by complement, charcoal stripping alone is enough. Every extra step costs growth-promoting proteins and adds a contamination risk.

Two ways to combine them

RouteHow it worksGood for
A: heat first, then charcoal56 °C for 30 min, then two charcoal rounds at 2–8 °CMost labs; gentlest on the serum proteins
B: charcoal at 56 °CThe first charcoal round runs at 56 °C for 45 min and heat-inactivates at the same timeVery low residual hormones in fewer working days

We describe route A in detail. Heating first has a practical advantage: the fine precipitate that forms at 56 °C is removed together with the charcoal by centrifugation and filtration, and nothing opens the bottle after the final sterile filtration.

Materials

  • FBS, thawed slowly at 2–8 °C
  • Water bath at 56 °C and a reference bottle with the same volume of water and a thermometer
  • Dextran-coated charcoal suspension: 0.25 % (w/v) activated charcoal and 0.025 % (w/v) dextran T-70 in buffer, stirred overnight at 2–8 °C
  • Centrifuge with bottles or tubes for the volume
  • 0.45 µm prefilters and a 0.2 µm sterile filter with low protein binding (PES)
  • Sterile tubes for aliquots

Step-by-step protocol (route A)

1. Heat-inactivate

  1. Mix the thawed serum by gently inverting the bottle.
  2. Place the bottle and the reference bottle in the 56 °C water bath.
  3. Start timing when the reference bottle reaches 56 °C and hold for 30 minutes. Swirl every 5–10 minutes.
  4. Cool the serum quickly to 2–8 °C.

2. First charcoal round

  1. Pellet a volume of charcoal suspension equal to the serum volume at about 500 × g for 10 minutes and discard the supernatant.
  2. Resuspend the pellet completely in the heat-inactivated serum.
  3. Incubate overnight (12–16 hours) at 2–8 °C with gentle, continuous mixing.
  4. Centrifuge at 500–1,000 × g for 10–15 minutes.

3. Second charcoal round

  1. Transfer the serum onto a fresh charcoal pellet and repeat the incubation.
  2. Centrifuge at 2,000–3,000 × g for 20 minutes to remove as much charcoal as possible.

4. Filter, aliquot, store

  1. Prefilter through 0.45 µm, then sterile-filter through 0.2 µm. Plan for several prefilters, because charcoal fines clog them quickly.
  2. Aliquot, label as “CS-HI” with date and lot, and store at −20 °C.

Route B in short

In route B the heat step and the first charcoal round are one step: incubate the serum with the charcoal pellet at 56 °C for 45 minutes, mixing regularly. Do the second round either at 56 °C again for the lowest residual hormones or overnight at 2–8 °C to spare heat-sensitive proteins. Then continue with the high-speed spin and filtration as in step 4.

Quality control

  • Hormones: measure the target hormones before and after treatment, by immunoassay or LC-MS/MS.
  • Complement: if your assay depends on it, check residual complement activity with a haemolysis assay.
  • Growth: compare growth and morphology of your cell line with untreated serum of the same lot.

Practical tips

  • Use phenol red-free medium for oestrogen studies. Phenol red acts as a weak oestrogen.
  • Do not heat a second time after stripping. It only degrades more protein.
  • Expect slower growth than with untreated serum. Adapt cells for a passage or two before the experiment.
  • Treat enough serum for the whole study from one lot, so all experiments use the same material.

Frequently asked questions

Should I heat-inactivate before or after charcoal stripping?

Before. The precipitate from heating is then removed with the charcoal, and the serum is not opened again after the final sterile filtration.

Does charcoal stripping at 56 °C replace heat inactivation?

Yes. A charcoal incubation of 45 minutes at 56 °C also inactivates complement, so a separate heat step is not needed.

Does the combined treatment remove viruses or mycoplasma?

No. Neither step is a reliable virus or mycoplasma safety step. For that, serum is gamma irradiated.

Can you prepare charcoal-stripped, heat-inactivated serum for us?

Yes. Heat inactivation and single or double charcoal treatment are part of our serum processing service, and we can apply both to the same lot. A test sample is available on request.

Related

Test sample of your lot

Test the exact lot before you order. If it works for you, we reserve it for up to 36 months – no prepayment.